The BACnet/IP driver allows the FieldServer to transfer data to and from devices over Ethernet using BACnet/IP protocol. The FieldServer can emulate either a Server or Client.
All information in a BACnet system is represented in terms of objects. The Object_Identifier is a 32-bit code that identifies the type of Object (also identified by the Object_Type Property) and its 'Instance' number, which together uniquely identify the Object within its BACnet device. Theoretically, a BACnet device could have over four million Objects of a particular type. The Object_Name is a text string, which has a unique capability.
BACnet devices may broadcast queries for devices that contain Objects with a specific Object_Name. This can greatly simplify project setup.
Thanks for you answer, but I cannot find this 'Gadget' driver manually. There is only this 'ELMO' driver and it is best available driver. In instruction is that use with 'SAM-BA' driver 'atm6124cdcsigned' driver. Mircom Group of Companies shall also not be liable for any damages that occur resulting from the use of improper Internet browser software (including the use of out-of-date or incompatible Internet browsers) or the use of improper audio or video drivers by users accessing the Mircom Group of Companies Website.
BACnet requires one Device Object to be present in every BACnet device. The Device Object makes information about the device and its capabilities available to other devices on the networks. Before one BACnet device starts control-related communications with another, it needs to obtain some of the information presented by the other device's Device Object. Unlike other Objects, the Device Object's Instance number must be unique across the entire BACnet internetwork because it is used to uniquely identify the BACnet devices. It may be used to conveniently identify the BACnet device from other devices during installation.
Standard object types are used to hold real time data and other information. Each Object Type is referenced by a number, for example 0 represents an Analog Input. See Appendix D.1 for abbreviation list.
Each Object consists of a number of prescribed properties, the main property being the Present_Value. Objects are monitored and controlled through their properties.
The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer.
Classic QuickServer Gateway (Serial-Ethernet)
QuickServer is a high performance, fully configurable, cost-effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.
System integrators worldwide have benefitted from the value of the powerful line of interoperability gateways offered by FieldServer. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion software on a highly cost-effective platform backed by the experience, engineering expertise and proven technical support that integrators have come to expect from FieldServer.
Mircom Driver Download
QuickServer (Serial-Ethernet) is available in two series:
The FS-QS-1X10 Series is preloaded with two BAS drivers (two RS485 serial ports and one Ethernet port) Drivers from a list of over 150 protocols. There is a basic QuickServer that can handle up to 250 points and an enhanced QuickServer that can handle 500 points.
The FS-QS-1220 Series is preloaded with two BAS drivers (one RS485 serial port, one RS232 serial port, and one Ethernet port) Drivers from a list of over 150 protocols. Each QuickServer can handle up to 500 points.
Each QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determination of status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discovery utility to determine what FieldServers are on a network.
BACnet MSTP
The BACnet Master-Slave/Token-Passing (MS/TP) driver implements a data link protocol that uses theservices of the RS-485 physical layer. See the FieldServer BACnet PIC statement for the level ofconformance that this driver implements.
All information in a BACnet system is represented in terms of objects. The Object_Identifier is a 32-bitcode that identifies the type of Object (also identified by the Object_Type Property) and its 'Instance'number, which together uniquely identify the Object within its BACnet device. Theoretically, a BACnetdevice could have over four million Objects of a particular type. The Object_Name is a text string, whichhas a unique capability. BACnet devices may broadcast queries for devices that contain Objects with aspecific Object_Name. This can greatly simplify project setup.
BACnet requires one Device Object to be present in every BACnet device. The Device Object makesinformation about the device and its capabilities available to other devices on the networks. Before oneBACnet device starts control-related communications with another, it needs to obtain some of theinformation presented by the other device's Device Object. Unlike other Objects, the Device Object'sInstance number must be unique across the entire BACnet internetwork because it is used to uniquelyidentify the BACnet devices. It may be used to conveniently identify the BACnet device from otherdevices during installation.
Standard object types are used to hold real time data and other information. Each Object Type isreferenced by a number, for example 0 represents an Analog Input.
Each Object consists of a number of prescribed properties, the main property being the Present_Value.Objects are monitored and controlled through their properties. The Analog Input Object is representativeof the Objects involved directly with control elements and many of its Properties reflect this.
The information that follows describes how to expand upon the factory defaults provided in theconfiguration files included with the FieldServer.
Quickserver Gateway (Serial-Ethernet)
The QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway forintegrators to easily interface devices to networks in commercial buildings and industrial plants.
System integrators world-wide have benefitted from the value of the powerful line of interoperability gateways offered byFieldServer. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion softwareon a highly cost effective platform backed by the experience, engineering expertise and proven technical support thatintegrators have come to expect from FieldServer.
QuickServer (Serial-Ethernet) is available in two series:
The QuickServer FS-QS-2X10 series is available at four different point capacities. Each QuickServer is preloaded with twodrivers (serial and/or Ethernet) from a customer’s choice of 140 different drivers, E.G. Modbus, BACnet, SNMP, EtherNet/IPand many more.
The FS-QS-2010 with 2 RS485 and 1 ethernet port can support up to 250 points. The FS-QS-2210 can support up to 500 points.The FS-QS-2310 can support up to 3,000 points. The FS-QS-2410 can support up to 5,000 points.
Equivalently the FS-QS-2020 with 1 RS485, 1 RS232 and 1 ethernet port can support up to 250 points. The FS-QS-2220 can support up to 500 points.The FS-QS-2320 can support up to 3,000 points. The FS-QS-2420 can support up to 5,000 points.
Every QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determinationof status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discoveryutility to determine what FieldServers are on a network.
Mircom PRO2000
The driver provides an interface to monitor a Mircom Pro2000 Fire Alarm Panel. It is able to readstatus data from the panel – when combined with another protocol driver this data can be servedusing another protocol such as BACnet, Lonworks, Johnson Controls N2, Rockwell, XML etc. Ablock diagram showing potential connectivity is provided below.
To avoid manual configuration the driver is provided with a utility that is used to aid in the creationof the FieldServer configuration.
This utility reads the PRO2000 Modbus CSV and uses this tomake BACnet objects, for each device connected to the system. One set of objects for eachdevice is created – reporting the alarm, trouble and other status info of the device. The ModbusCSV file is created when the panel is configured and is provided by the engineer who configuresthe fire alarm panel.
This is an active client driver – it sends commands and polls and the panel responds with data.The driver cannot be used to emulate a PRO2000 ( cannot be used as a server).
The driver supports a small subset of the command/query functions and assumes the deviceshave been configured correctly and appropriately to achieve the control required.
Specifications
Classic QuickServer Gateway (Serial-Ethernet)
Classic QuickServer Specs: FS-QS-1XX0
Depending on what hardware you require, the specifications will contain different options. For Example, M-bus section is only available on the FS-QS-1x50/FS-QS-1x51 devices where x is A for 16 devices, B for 32 devices and C for 64 devices. See images below for Port Support and product code check.
Environment
- Operating Temperature: -40 to 75oC (-40 to 167oF)
- Relative Humidity: 5-90% RH non-condensing
Power Requirements
9-30V DC or 12-24V AC, RS-422 = 15-30V DC or 12-24V AC, M-Bus = 12-24V DC (Slave: 550 mA, Master (1 Slave): 580 mA, Master (64 Slave):980 mA); 240 mA
Physical Dimensions
- Dimensions (WxDxH): 4.5x2.9x1.6 in (11.5x7.4x4.1cm)
- Weight: 0.4 lbs (0.2 Kg)
Other
- Configuration/Diagnostic utilities
- Capacity, max points: 250 for QS-10XX, 500 for QS-12XX, 3000 for QS-13XX, 5000 for QS-14XX
- Table, Wall or DIN rail mount
Communication
- Baud: 4800, 9600, 19200, 38400, 57600, 115200
- Start Bit: 7, 8; Stop Bit: 1, 2
- Parity: Even, Odd, None
LonMark Certification (FS-QS-1XX1)
- SPID: 80:00:95:46:00:84:04:01
- Profiles: 0000 - Node object, 0001 - Open Loop Sensor Object, 0003 - Open Loop Actuator Object
- Ethernet: 1, 2
- Parity: 10/100 BaseT
Approvals
- TUV Approved: to UL 916, EN 60950-1, EN 50491-3 and CSA C22.2 standards
- BTL Mark, RoHS Compliant, GOST-R Certified, CE and FCC
- LonMark Certified: (FS-QS-1011/FS-QS-12X1)
Quickserver Gateway (Serial-Ethernet)
Mircom Driver Download Windows 7
QuickServer Specs: FS-QS-2XX0
Environment
- Operating Temperature: -20 to 70°C (-4 to 158oF)
- Relative Humidity: 10-95% RH non-condensing
Power Requirements
- Intput: 24VAC 0.125A, 12-24VDC 0.25A @12 VDC
- Max Power: 3W
Physical Dimensions
- Dimensions (WxDxH): 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
- Weight: 0.4 lbs (0.2 Kg)
Other
Web configuration
On-board diagnostics
DIN rail mount included
- Capacity: 250 points FS-QS-20XX, 500 points FS-QS-22XX, 3000 points FS-QS-23XX, 5000 points FS-QS-24XX
Communication
FS-QS-2XX0
- Baud: 9600, 19200, 34800, 57600, 76800
- Serial (Galvanic Isolation) Ports: 1 x RS485, 1 x RS232/RS485
- Ethernet Port: 10/100baseT, MDIX, DHCP
Approvals
- UL 60950
- IC Canada
- RoHS Compliant
- WEEE compliant
- RoHS compliant
- CE and FCC class B and C part 15
Block Diagrams
Manuals
Datasheets
Case Studies
Additional Information
BACnet MSTP to IP
A BACnet Router is used to connect MSTP trunks to BACNetIP systems. The router itself is a device on the IP and on the MSTP side. The router can also act as BBMD device allowing messages to cross from one subnet to another.
Mircom Driver Download Windows 10
BACnet BBMD
Mircom Software Download
BACnet messages cannot cross from one subnet to another except under special circumstances.
Most BACnet sequenc es of messages begin with a broadcast called 'who is'. All devices respond with 'I am'. That is how they are discovered. It is also how many system confirm the device is still there.
Broadcasts can't cross routers (they are blocked) and therefore devices on the other side of a router cannot e discovered.
BBMD is the name of the BACNet technology that resolves these issues. The BACNet ROuter sold by CAS provides BBMD services as do all FieldServer BACNet products when configured as clients.
Articles
RS485 Networks – Multiple Protocols
BACnet MSTP Installation, RS485 and Cables
BACnet MSTP Topology (RS485)
What can go wrong with 485 and BACnet MSTP ?
BACnet MSTP (RS485) – Bandwidth usage
Segmentation in BACnet
Useful Links
Logos
I'm novice with ARM and have problems with USB to Serial Converter. Operation system is Windows 7. Installation (atm6124_cdc.inf) itself went okey, but the following message appears:
'The software for this device is now installed, but may not work correctly. This device cannot start. (Code 10)'.
Mircom Driver Download Pc
Do you have some tips and tricks how to install this correctly.
Mircom Driver Download Software
I have wireless mouse installed in one USB port and I have also VirtualBox in my machine. Hopefully these are not the problem.